2. Extend against the stop the handle of control of the air gate. Create vacuum in an air chamber of the gate and measure a gap And which has to conform to the requirements provided in subsection 6.1.1 (In – the adjusting screw).
3. If necessary make adjustment by the screw located on the vacuum chamber.
4. Check a gap between a control lever flaps of the deflector and draft of movement.