Model 2,0 with 16 valves |
1. Lift a forward part of the car and fix on supports. |
2. Remove a weight wire from the accumulator. |
|
3. Remove the thermofilter of a collector which from above fastens three bolts, and from below – two nuts of fastening of a collector. |
4. Unscrew 10 nuts fixing a final collector. |
|
5. On models with the sensor of oxygen disconnect the electric socket of the sensor which is about the top fastening of the right suspension bracket, and release the wires going to the sensor. Working under the car, unscrew a bolt of elastic fastening of a final collector and an arm. |
6. Remove a final collector and laying of a collector. |
Other models
|
7. You watch the corresponding description in subsection 6.1.16. On models with the sensor of oxygen disconnect the electric socket of the sensor of oxygen and release the wires going to the sensor not to damage a wire at removal of a collector. |