8.1.4. Removal and installation of contacts of the breaker
In the presence of pointed corrosion or an obgoraniye of contacts they need to be replaced.
Removal
PERFORMANCE ORDER |
|
1. Unscrew two screws and uncover the distributor of ignition and an ignition distributor rotor a distributor shaft. |
|
2. Move a spring of the lever of contacts of the breaker from the plastic insulator and disconnect a wire from contacts. |
|
3. Unscrew the screw (is specified by an arrow) fixing a plate of the breaker of contacts to a basic plate of the distributor of ignition and remove contacts of the breaker. |
|
Installation
PERFORMANCE ORDER |
1. Installation is made in the sequence, the return to removal. |
2. Check a gap between contacts of the breaker or a corner of the closed condition of contacts of the breaker and, if necessary, adjust them. |
3. Then establish a rotor of the distributor and a cover of the distributor of ignition. |
|